Nominal quantities
Vpack = S × Vcell
Ahpack = P × Ahcell
Whpack = Vpack × Ahpack
The user-entered voltage is an assumed OCV for the load calculation. A true cell's OCV varies with state of charge and chemistry.
The free CAD studio uses one project document containing cell coordinates, enclosure vertices, and manually modeled conductors. Both the large interactive 3D view and binary STL export use the same geometry; electrical calculations are intentionally gated on completeness of the simplified model.
Cylindrical cell meshes use nominal diameter and height in millimeters. The case boundary is a 2D polygon and an extruded reference base; it is not a manufacturable wall or tolerance-complete enclosure. Editing a cell's X/Z position updates its solid and drawing. The planar checker tests the full nominal circle against the polygon and flags center-to-center distances below cell diameter plus a user-chosen nominal clearance.
Busbars are extruded polygon ribbons derived from editable multi-point centerlines. Their mesh is an idealized strip; it does not include weld nuggets, bends, real contacts, insulation, terminals, or manufacturing tolerances. STL files carry actual reference triangles in millimeter coordinates, not STEP design intent or production authorization.
The user declares S series groups and P cells per group, then must populate all groups equally and create one modeled adjacent-group busbar record between each consecutive group. This is an abstract circuit topology gate, not proof that the drawn conductor touches the right polarities, carries the load, or is safe. The studio intentionally withholds its loaded terminal-voltage number until those simplified requirements and basic planar geometric clearances are met.
The fixed-parameter zero-order Thevenin estimate uses entered open-circuit cell voltage, capacity, and DC internal resistance. For an assumed balanced S/P arrangement:
Vpack = S × Vcell
Ahpack = P × Ahcell
Whpack = Vpack × Ahpack
The user-entered voltage is an assumed OCV for the load calculation. A true cell's OCV varies with state of charge and chemistry.
Rcells = S × (Rcell / P)
Rbar = ρ × L / (width × thickness)
Vloaded = Voc,pack − I × Rtotal
Qloss = I² × Rtotal
All conductor dimensions are converted to SI units. Resistivity is a fixed nominal value near 20°C. Contact resistance is entered as one lumped estimate.
For a specified constant-power demand, the smaller positive root of P = I × (Voc,pack − I × Rtotal) gives the estimated operating current. Requests exceeding the maximum modeled power are rejected rather than silently inventing a solution.
The studio does not solve actual circuit polarity and weld topology, contact microgeometry, internal cell heating, temperature rise, thermal runaway, conductor ampacity under real cooling conditions, BMS wiring, fuses, manufacturing constraints, mechanical stress, abuse scenarios, faults, or regulatory compliance. The same drawn arrangement may perform very differently depending on chemistry, SOC, temperature, contact resistance, and aging.
In particular, calculated I²R loss is not a cell-temperature prediction. A model can use mathematically correct equations and still make a poor physical prediction if its parameters are wrong. Users should use validated manufacturer data, measured characteristics, and qualified engineering review for actual pack design.
NREL — Battery Lifetime Analysis (BLAST): electrical models using OCV and resistance dependent on SOC and temperature.
Oak Ridge National Laboratory — DER Device Models: simple ohmic battery model and parameter dependence.
Published battery-pack model validation against experimental data: explains why physical measurement is necessary.