Free battery voltage drop calculator
Model the first-order DC effects of current load on an assumed series/parallel pack. Our free interactive battery studio combines layout grouping, user-defined cell parameters and actual busbar polyline lengths. No login or purchase required.
Nominal voltage, amp-hours and energy
For a balanced S×P grouping with S series groups and P identical cells per group, the standard idealized relationships are Vnom = S·Vcell, Ahpack = P·Ahcell, and Whnom = S·P·Vcell·Ahcell. For example, an assumed 6S4P pack of 3.6 V / 3.0 Ah cells has nominal voltage 21.6 V, capacity 12 Ah and nominal energy 259.2 Wh. These values only apply to a hypothetical correctly assembled network with matched cells.
Voltage under electrical load
Use a manufacturer-tested DC internal resistance for each cell rather than assuming chemistry-specific values. Under a simplified steady DC model, cell-group resistance is Rcell/P and total cell-pack resistance is S·Rcell/P. Added resistances are contact resistance and explicitly modeled series busbar paths. The terminal-voltage estimate becomes Vloaded ≈ (S·Vcell) − I·Rtotal. Resistive heat dissipation is Pheat = I²·R for each modeled element.
Important limitation: nominal voltage is not actual open-circuit voltage at a given state of charge. A real load-dependent cell model requires measured SOC-dependent voltage curves, temperature, age, transients and BMS behavior. Estimates may be inaccurate at high current, near cutoff and with complex busbar networks.
What the copper and nickel route lengths mean
For a uniform straight conductor of length L and cross-section area A, approximate electrical resistance at room temperature is R = ρL/A. In the editor, L is the sum of user-drawn line segments and A is user-entered width × thickness. A “modeled series path” contributes to the estimated pack drop; a “visual-only” path does not. Parallel branching, terminal connections, welds and geometry-dependent current crowding are not solved.
Do not turn a voltage estimate into a safety rating
The displayed calculated loaded voltage and heat do not validate protection, insulation, cell matching, conductor ampacity, soldering or welding, fusing, BMS, enclosure clearance, temperature rise, thermal runaway protection or regulatory compliance. Use independently validated engineering and appropriate qualified review for real builds.
Published reference
Battery University: Series and Parallel Battery Configurations explains how series cells add voltage and parallel cells add amp-hour capacity. The tool's electrical formulas are simple circuit identities, not licensed safety ratings.